# DANOPLUS K Type Thermocouple Thermometer -200~1372℃ (2501℉) | Dual Channel HVAC Temperature Meter Gauge

**Brand:** DANOPLUS
**SKU:** avk1751
**ASIN:** B0BJQ95RRZ
**Canonical URL:** https://crowcrowcrow.com/p/thermocouple-thermometer-digital-type-thermocouples-328-2500-measuring-range-hvac-dual/avk1751
**Category:** health-supplement
**Subcategory:** Categories
**Availability:** in_stock
**Price (INR, all-inclusive):** ₹4,440
**Discount:** 13%
**Customer rating:** 4.20/5 from 383 ratings

## Description

DANOPLUS K Type Thermocouple Thermometer measures -200~1372°C (-328~2501°F) with dual channels and 4 probes. Features HD LCD, °C/°F switch, alarms, and calibration. Ideal for HVAC, industrial, and lab use. Imported from USA, all duties included. Arrives via ExpressBox with {{ccc_delivery_eta}}.

## Highlights

- Wide Temperature Range — Measures -200~1372°C (-328~2501°F) with K-type probes (-50~700°C) and bead probes (-20~200°C), suitable for extreme industrial and lab conditions.
- Dual Channel Precision — Simultaneously monitor two temperature points (T1 & T2) or calculate the difference, crucial for process control and diagnostics in HVAC and manufacturing.
- Adjustable Hi/Low Alarm — Set custom upper and lower temperature thresholds with a red backlight flash alert, ensuring critical process parameters are always monitored.
- User-Calibratable — Features ADJ compensation for manual calibration within -9~9℃, allowing users to fine-tune accuracy for specific industrial or laboratory standards.

## Key features

- ✅ 【Wide Measurement Range】The main unit measuring range is: -328~2501℉(-200~1372℃); Range of K type thermocouple(Stainless Steel):-58~1292℉(-50~700°C); Bead-type thermocouple(blue):-4~392℉(-20~200°C)
- ✅【Multi-Functional】: HD large screen display, ℉/℃ and K/J switchable, Max/Min/Average, Data Hold, Auto power-off function(can be cancelled manually)
- ✅【Differential Temperature】Long press T1-T2 or T2-T1, and find the difference temperature value between T1&T2 testing samples easily
- ✅【Hi/Low Flash Alarm】Manually set the upper and lower alarm thresholds. The red backlight of the screen will flash when the testing value is higher or lower than the set thresholds
- ✅【ADJ compensation】Long press Hi and Low button together, adjust the ADJ compensation value to complete the calibration procedure, ADJ compensation range: -9~9℃

## Why choose this product

- This DANOPLUS K Type Thermocouple Thermometer delivers the precision required for India's diverse industrial, HVAC, and laboratory needs. Its wide temperature range and dual-channel capability allow for accurate monitoring in challenging environments, from manufacturing floors to research facilities. Unlike generic local alternatives, it offers advanced features like differential temperature measurement and user-adjustable calibration, ensuring your critical processes remain within optimal parameters. Imported directly from authorized US retailers, it guarantees authentic performance for demanding applications. — Precision for Indian Industries
- This instrument is designed for industrial, HVAC, and laboratory use, not for measuring human body temperature. Professionals in manufacturing, food processing, or research will find its wide range and dual-channel functionality invaluable. However, individuals seeking a thermometer for medical purposes, such as checking fever, should look for dedicated clinical thermometers. This device's high temperature capabilities and probe types are optimized for inanimate objects and environments, not biological readings. — Ideal for Professionals, Not for Personal Health

## How to use

1. Insert the K-type or bead-type thermocouple probes into the T1 and T2 input jacks on the thermometer. Ensure the positive (+) and negative (-) connections are correctly aligned for accurate readings. — Connect Thermocouple Probes
2. Power on the device and press the °C/°F button to select your desired temperature unit. The thermometer automatically adjusts to the appropriate range based on the connected probe type. — Select Units and Range
3. Place the probe tips at the measurement points. Use the Max/Min/Avg, Data Hold, or Differential Temperature (T1-T2) functions as needed. Set the Hi/Low alarm thresholds by pressing the respective buttons. — Take Measurements and Use Features
4. If calibration is needed, long-press the Hi and Low buttons together to adjust the ADJ compensation value. Press the power button to turn off the device; it will also auto-power off after a set period if not manually deactivated. — Calibrate and Power Off

## Product details

| Field | Value |
|---|---|
| Included Probes | 2 x K-Type Metal Probes, 2 x Bead-Type Thermocouples |
| Probe Material | Stainless Steel (K-Type) |
| Main Unit Measuring Range | -200~1372°C (-328~2501°F) |
| K-Type Probe Range | -50~700°C (-58~1292°F) |
| Bead-Type Probe Range | -20~200°C (-4~392°F) |
| Temperature Units | °C / °F switchable |
| Accuracy | ±0.5°C (±1°F) for main unit, ±(0.5% + 1°C) for probes (typical) |
| Resolution | 0.1°C/°F up to 999.9, 1°C/°F above 1000 |
| Calibration Adjustment | ADJ compensation range: -9~9℃ |
| Primary Use | Industrial, HVAC, Laboratory, Food Processing |
| Differential Temperature | Yes (T1-T2 or T2-T1) |
| Alarm Function | Hi/Low Flash Alarm |
| Data Hold | Yes |
| Max/Min/Average | Yes |
| Response Time | 0.5 seconds |
| Cost per use | Reusable instrument — {{ccc_price_per_unit:1:unit}} (for the device itself) |
| Shelf life after opening | N/A (Durable electronic device) |
| Contraindications | Not for medical/body temperature measurement |
| Allergens / common irritants | None |
| Brand | DANOPLUS |
| Model Name | DP-343 |
| Part Number | DP-343 |
| Color | Black |
| Material | Stainless Steel (probes) |
| Style | Compact |
| Display Type | HD LCD with LED Backlight |
| Dimensions (Unit) | 21.8 cm x 9.3 cm x 5.2 cm (8.6 x 3.7 x 2.0 inches) |
| Item Weight | 0.25 lbs (0.11 kg) |
| Package Weight | 0.3 kg (0.66 lbs) |
| Power Source | 3 x AAA Alkaline Batteries (included) |
| Auto Power-Off | Yes (manual override) |
| Certifications | CE |
| Country of Origin | Not stated by manufacturer — US retail version, sourced from authorized US retailers |

## Frequently asked questions

### Is this DANOPLUS K Type Thermocouple Thermometer suitable for measuring body temperature?

This is an industrial/scientific temperature instrument designed for process, lab, food, or HVAC measurement rather than clinical body-temperature use. Its wide range and probe types are optimized for inanimate objects and environments, not biological readings. Check the listed temperature range and probe type to confirm it matches your intended application.

### Can I switch the display between Celsius and Fahrenheit?

Yes, the DANOPLUS K Type Thermocouple Thermometer features a switchable display allowing you to select between Celsius (°C) and Fahrenheit (°F) readings. This ensures compatibility with various industry standards and user preferences, with Celsius being the default for many Indian scientific and food safety applications.

### How accurate is this digital thermometer?

The main unit offers a typical accuracy of ±0.5°C (±1°F), while the probes have a typical accuracy of ±(0.5% + 1°C). For critical applications, the ADJ compensation feature allows manual calibration within a -9~9℃ range to fine-tune readings for specific industrial or laboratory standards.

### What is the temperature range for the included thermocouples?

The included K-type metal probes measure between -50~700°C (-58~1292°F), and the bead-type thermocouples measure -20~200°C (-4~392°F). The main unit itself can measure a much wider range from -200~1372°C (-328~2501°F).

### Does this thermometer have an alarm function?

Yes, the DANOPLUS thermometer features a Hi/Low flash alarm. You can manually set upper and lower temperature thresholds, and the red backlight will flash when the measured value exceeds these set points, providing an immediate visual alert for critical process monitoring.

### How to choose a thermometer for HVAC and industrial use in India?

For HVAC and industrial use in India, choose a digital thermometer with a wide temperature range, dual-channel capability, and robust probe types like K-type. Ensure it offers °C/°F switching and has features like alarms and calibration adjustment for precise monitoring in varying ambient conditions.

### What are the benefits of using a dual-channel thermometer?

Dual-channel thermometers, like this DANOPLUS model, allow you to measure two temperatures simultaneously or calculate the difference between them (T1-T2). This is highly beneficial for diagnosing HVAC systems, monitoring heat transfer, or comparing temperatures in industrial processes, providing deeper insights than single-channel devices.

## Compliance

No product-specific compliance warnings identified. Standard imported-goods terms apply: customs duties & GST paid; for personal use in India; follow the manufacturer's usage instructions on the packaging.

## Images

1. https://images.crowcrowcrow.com/B0BJQ95RRZ-2.webp
2. https://images.crowcrowcrow.com/B0BJQ95RRZ-5.webp
3. https://images.crowcrowcrow.com/B0BJQ95RRZ-8.webp
4. https://images.crowcrowcrow.com/B0BJQ95RRZ-11.webp
5. https://images.crowcrowcrow.com/B0BJQ95RRZ-14.webp
6. https://images.crowcrowcrow.com/B0BJQ95RRZ-17.webp

---

Source: https://crowcrowcrow.com/p/thermocouple-thermometer-digital-type-thermocouples-328-2500-measuring-range-hvac-dual/avk1751

Returns: 30 days, free, by mail. Shipping: Free across India, 7–13 business days. Prices are all-inclusive (duties + GST).